03 380 RF Power Supply

06 380 RF Power Supply is 300 Watts RF Power at 380 kHz for Industrial and Laboratory Applications.

PDF DOWNLOADS:

 
 

STANDARD FEATURES

  • 380 kHz up to 300 Watts
  • Low distrortion level < -45 dBc
  • Measuring forward, reflected and load power and power VSWR simultaneously
  • Back panel control & monitoring of all functions
  • Data acquisition: Status Monitoring & Power Measurement at Analog & Digital Ports
  • AGC Power Leveling: Gain Control to withing +/-2W
  • Pulse operation from 2mu and up in BURST mode
  • INternal or External signal source (amplifier operation)

SPECIFICATIONS

DESCRIPTION RANGE/CHARACTERISTIC
Class of Operation Class B
Frequency of Operation / Frequency Stability
380 kHz (+/- 5kHz); 0.0005% or better
RF Power Output 300 Watts into 50 Ohm
Output(as amplifier) in MGC/Burst Mode 0 dBm IN, 1V (5 or 10V) CTL IN pin 5 100W ±2W
RF Input Drive(as amplifier) Typical range -20 dBm to 0dBm, 1V (5 or 10V) CTL IN pin 5
RF Input Drive for AGC Recommended +0 to +3 dBm for the best operation
Input Drive Source(amplifier) Signal or function generator, analog computer input capable of up to 2 Vp-p @ 50 Ohm
Internal RF Source Crystal oscillator at 380 kHz +/-5 kHz
Input and Output Impedance
50 Ohm
Input VSWR 1.2:1 max
Output VSWR 3:1 max
Output VSWR Protection 80W max reflected power limit. Automatic, limits typically within 0.5 ms after reverse power reaches 80W or power amplifier current preset limit.
Harmonic level @ 550W
Better than - 45 dBc
Spurious Output - 50 dBc
Output Blanking For pulsed applications, T&C amplifiers and generators offer blanking of the output signal for minimum noise RF spectrum
Dynamic Power Range 1 to 300W, settings within +/-2W
Output Settings & Control (Communications) SubD 25 Analog and Digital I/O.
Port Power scale 1V=100W. Rear Panel
Pulse Specifications Pulse Width from 2 mu to continues, user defined
Power Margin 20%
RF Input / Output connectors

INPUT BNC Female
OUTPUT N Female
BLANKING BNC Female
Rear Panel

AC Power Source 100 to 120, 200 to 240 VAC, +/-10%, 50-60 Hz,
broad input voltage with no adjustment required.
AC Power connection IEC Standard Power Entry followed by RFI filter. Filter range 0.1 to 30 MHz min.
AC Circuit Protection Internally fused on the main DC Power Supply, 15A
AC Input Current (RMS) RF Out 600W:
100-120 VAC ac, max. I =10A,
200 to 240V ac, max I =5A
Cooling Forced air, temperature controlled heatsink temperature monitored for equipment safety at 70C limit.
Dimensions (with hardware) H135mm x W211mm x L356mm ( 5.25” H x 8.3” x 14” )
Weight 14.5 kg, 32 lbs.
Mounting Half Rack, 3U high. Optional: Rack Mount Kit, Adapter Kit, Coupling Screws.
Environmental conditions Temperature: 10° to 40° C ambient air
Humidity: 80%
Equipment intended for ISM applications in laboratory and light industrial environment.
 