1213 RF Generator

1213 RF Generator

1213 RF Generator is 1200 Watts RF Power at 13.56 MHz
for Industrial and Laboratory Applications.

PDF DOWNLOADS:

 
 

STANDARD FEATURES

  • 13.56 MHz up to 1200 Watts
  • Low harmonic level at 1000W h2< -45 dBc, h3 and higher < -55 dBc
  • Measuring forward, reflected and power VSWR simultaneously
  • Back Panel Control & Monitoring of all Generators functions. Data acquisition: Status Monitoring & Power Measurement via Analog Port
  • AGC Power Leveling: Output Power Control to better than +/-10W of set value.
  • Pulse operation in MGC/Burst Mode

SPECIFICATIONS

DESCRIPTION RANGE/CHARACTERISTIC
Class of Operation Class C
Frequency of Operation / Frequency Stability
13.56 MHz default / 0.005%
RF Power Output 1200 Watts into 50 Ohm
Output(as amplifier) in MGC/Burst Mode 0 dBm IN, 10V CTL IN pin 5 1000W ±10W
RF Input Drive for AGC Recommended +0 to +1.5 dBm for the best operation
Input Drive Source(amplifier) Signal or function generator, analog computer input capable of up to 2 Vp-p @ 50 Ohm
Internal RF Source Crystal oscillator at 13.56 MHz
Input and Output Impedance
50 Ohm
Input VSWR 1.2:1 max
Output VSWR 3:1 max
Output VSWR Protection 240 W max reflected power limit. Automatic foldback limit with [W] level of protection depending on actual VSWR of a load connected.
Harmonic level @ 550W
Better than - 45 dBc for 2-nd harmonic, any other > -55 dBc
Spurious Output - 55 dBm equivalent noise level generated by internal circuits
Output Blanking For pulsed applications, T&C amplifiers and generators offer blanking of the output signal for minimum noise RF spectrum
Dynamic Power Range 10 to 1200W, settings within +/- 10W
Output Settings & Control (Communications) SubD 25 Analog and Digital I/O.
Port Power scale 1V=100W. Rear Panel
Pulse Specifications Pulse Width from 2 mu to continues, user defined
Power Margin 30%
RF Input / Output connectors

INPUT BNC Female
OUTPUT N Female
BLANKING BNC Female
Rear Panel

AC Power Source 200 - 240 VAC, +/-10%, 47 - 63 Hz,
broad input voltage with no adjustment required.
AC Power connection IEC Standard Power Entry followed by RFI filter. Filter range 0.1 to 30 MHz min.
AC Circuit Protection Internally fused on the main DC Power Supply, 15A
AC Input Current (RMS) I<10A @ 220V
Cooling Forced air, temperature controlled heatsink temperature monitored for equipment safety at 70C limit.
Dimensions (with hardware) H135mm x W224mm x L445mm ( 5.25” H x16.6” x 17.5” )
Weight 14 kg, 31 lbs.
Mounting 19" Rack, 3U high. Optional: Rack Mount Kit, Adapter Kit, Coupling Screws.
Environmental conditions Temperature: 10° to 35° C ambient air
Humidity: 80%
Equipment intended for ISM applications in laboratory and light industrial environment.
 