| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class C/D |
| Frequency of Operation
/ Frequency Stability |
13.56 MHz default / 0.005%
|
| RF Power Output |
up to 2500 Watts
into 50 Ohm |
| Output(as amplifier)
in MGC/Burst Mode |
0 dBm IN, 10V CTL
IN pin 5 1000W ±10W |
| RF Input Drive for AGC |
Recommended +0 to +1.5 dBm for
the best operation |
| Input Drive Source(amplifier) |
Signal or function
generator, analog computer input capable of up to 2 Vp-p
@ 50 Ohm |
| Internal RF Source |
Crystal oscillator
at 13.56 MHz |
- Input and Output Impedance
|
50 Ohm |
| Input VSWR |
1.2:1 max |
| Output VSWR |
3:1 max |
| Output VSWR Protection |
400 W max reflected
power limit. Automatic foldback limit with [W] level of
protection depending on actual VSWR of a load connected. |
Harmonic level @ 550W
|
Better than - 45 dBc for 2-nd
harmonic, any other > -55 dBc |
| Spurious Output |
- 55 dBc equivalent noise level
generated by internal circuits |
| Output Blanking |
T&C amplifiers
and generators offer blanking of the output signal for
minimum noise RF spectrum |
| Dynamic Power Range |
~ 1 to 2400W, settings
within +/- 15W |
| Output Settings &
Control (Communications) |
Basic Model: SubD 25 Analog and Digital I/O.
Port Power scale 10V and 5V scales. Rear Panel.
D-Comm Models: RS 232, 485 and USB.
|
| Pulse Specifications |
Pulse Width from
2 us to continues, user defined |
| Power Margin |
100%. NOTE! End
stage Pdc at water Temp 25C. |
| RF Input / Output connectors |
INPUT BNC Female
OUTPUT N Female
BLANKING BNC Female
Rear Panel
|
| AC Power
Source |
200 - 240 VAC, +/-10%,
50 - 60 Hz,
broad input voltage with no adjustment required. |
| AC Power connection |
Permanently attached
line cord with plug (meeting safety requirements of the
region where equipment will be operating). PFC of 95%
at 230 VAC. |
| AC Circuit Protection |
Back Panel Circuit Breaker,
20A |
| AC Input Current (RMS) |
I<20A @ 220V |
| Cooling |
Water cooled and forced air, heatsink temperature monitored
for equipment safety at 70C limit.
Water flow >1.5 GPM (6 LPM) and temperature 20C-25
C.
|
| Dimensions (with hardware) |
H135mm x W224mm x L445mm ( 5.25
H x16.6 x 17.5 ) |
| Weight |
20 kg, ~ 42lbs. |
| Mounting |
19" Rack,
3U high. Optional: Rack Mount Kit, Adapter Kit, Coupling
Screws. |
| Environmental conditions |
Temperature: 10°
to 40° C ambient air
Humidity: 80%
Equipment intended for ISM applications in laboratory
and light industrial environment. |