| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class C/D |
| Frequency of Operation
/ Frequency Stability |
13.56 MHz default / 0.005%
|
| RF Power Output |
1200 Watts into
50 Ohm |
| Output(as amplifier)
in MGC/Burst Mode |
0 dBm IN, 10V CTL
IN pin 5 1200W ±12W |
| RF Input Drive for AGC |
Recommended +0 to +3 dBm for
the best operation |
| Input Drive Source(amplifier) |
Signal or function
generator, analog computer input capable of up to 2 Vp-p
@ 50 Ohm |
| Internal RF Source |
Crystal oscillator
at 13.56 MHz |
- Input and Output Impedance
|
50 Ohm |
| Input VSWR |
1.2:1 max |
| Output VSWR |
3:1 max |
| Output VSWR Protection |
250 W max reflected
power limit. Automatic foldback limit with [W] level of
protection depending on actual VSWR of a load connected. |
Harmonic level @ 550W
|
Better than - 50 dBc for 2-nd
harmonic, any other > -55 dBc |
| Spurious Output |
- 55 dBm equivalent noise level
generated by internal circuits |
| Output Blanking |
For pulsed applications,
T&C amplifiers and generators offer blanking of the
output signal for minimum noise RF spectrum |
| Dynamic Power Range |
3 to 1200W, settings
within +/- 12W |
| Output Settings &
Control (Communications) |
SubD 25 Analog on Basic model. Port Power scales:
5V and 10V (default). Rear Panel
SubD 25 Analog and Digital I/O on D-Comm models.
RS 232, 485 and USB. Rear Panel.
Front panel controls, back panel Analogue and Digital
communications for AG 1213W model.
|
| Pulse Specifications |
Pulse Width from
2 mikroseconds to continues, user defined |
| Power Margin |
120% Note! End
Stage Pdc margin @ 25C water temp. |
| RF Input / Output
connectors |
INPUT BNC Female
OUTPUT N Female
BLANKING BNC Female
Digital I/O (optional): RS232, USB2 and RS485
|
| AC Power
Source |
200 - 240 VAC, +/-10%;
50/60 Hz, +/-10%
(100 to 120 VAC operation possible at up to 50% output
level) |
| AC Power connection |
Permanently attached
line cord with plug (meeting safety requirements of the
region where equipment will be operating). PFC of 95%
at 230 VAC. |
| AC Circuit Protection |
Back Panel Thermal Circuit Breaker,
12A |
| AC Input Current (RMS) |
RF Out 1200W: I<9A @ 220V |
| Cooling |
Water cooled and forced air, heatsink temperature monitored
for equipment safety at 70C limit.
Water flow >1 GPM (4 LPM) and temperature 20C-25
C.
|
| Water Inlet and Outlet |
The connection provided accepts
a 1/4-inch NPT male pipe thread. |
| Case |
Designed to meet EMI and RFI shielding requirements
aluminum natural finish.
Front Panel: T&C off white for 1213W
(basic) and 1213W D-Comm models. Plastic overlay
with membrane switches for AG 1213W models.
|
| Weight |
9.5 kg, 21 lbs. |
| Mounting |
1/2" Rack,
3U high. Optional: Rack Mount Kit, Adapter Kit, Coupling
Screws. |
| Dimensions
(with hardware) |
H135mm x W212mm x L482mm ( 5.25 H x8.3
x 19 )
|
| Environmental
conditions |
Temperature: 10°
to 40° C ambient air
Humidity: 80%
Equipment intended for ISM applications in laboratory
and light industrial environment. |