Physical
|
01-100W
|
03-300W
|
06-600W
|
12-1200W
|
Notes
|
|
Dimensions
|
5.25"x 8.3"x14" / 135x211x356mm
|
5.25"x 8.3"x17.5"
135x211x445mm
|
Please contact T&C for details
on select model.
|
|
Weight
|
|
23.5 lbs
10.5 kg
|
24 lbs
11 kg
|
32 lbs
14.5 kg
|
|
|
|
|
Electrical
|
01-100W
|
03-300W
|
06-600W
|
12-1200W
|
|
|
AC line INPUT
|
100 to 120, 200 to 240 VAC, 50/60
Hz
|
200 to 240 VAC
50/60 Hz
|
|
|
Frequency
|
Your RF power supply may be specified
with on of the following operating frequencies:
40 kHz, 80 kHz, 380 kHz, 450 kHz, 3 MHz, 13.56 MHz,
27.12 MHz, 40.69 MHz
|
Please contact T&C for details
and most popular units
|
|
RF Output
|
> 100W into 50 Ohm
|
> 300W into 50 Ohm
|
> 600W into 50 Ohm
|
> 1.2kW into 50 Ohm
|
|
|
Dynamic Range
|
1 to 120 W
|
1 to 310 W
|
2 to 610 W
|
2 to 1200 W
|
|
|
Output Settings
|
Within +/- 2W
|
Within +/- 2W
|
Within +/- 5W
|
Within +/- 10W
|
|
|
Pulse Operation
|
BURST: RF pulse width from 2MUs to
continuous; user defined
BLANKING: when applied the output is OFF for user defined
time.
Rise/Fall times under 100 ns.
|
|
|
Harmonics
|
Better than -40dBc when operated into
a 50 Ohm non-reactive load
|
Please contact T&C for details
and most popular units
|
|
|
|
Communications
|
The "XX" family offers multiple
communication models:
BASIC- Analog 25 pin communications with 1V, 5V and
10V scaling, EXT RF IN, BURST and BLANKING
D-Comm - RS232, RS484 USB as standard. Profitbus and
DeviceNet protocols optional + BASIC
H-I (Human Interface) full control of the generator
form the Front Panel + BASIC + D-Comm
|
|
|
|
|
Environmental
|
01-100W
|
03-300W
|
06-600W
|
12-1200W
|
|
|
Ambient operating temperature
|
5 C to 35 C
|
|
|
Cooling
|
Air Cooling, Front intake, Rear exhaust
|
Please contact T&C for other options
|
|
|
|
Regulatory
|
CE marked for EN61010-1 and UL 61010-1
Meet FCC part 18 requirements for ISM equipment
|
|
|
|