| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class B |
| Frequency of Operation
/ Frequency Stability |
13.56 MHz default, adjustable from 13.3
MHz to 13.8 MHz/ 0.005%
|
| RF Power Output |
>100 Watts into
50 Ohm |
| Gain(as amplifier)
in MGC/Burst Mode |
52 dB @ 100W +/-1dB
(0dBm IN Drive) |
| RF Input Drive(as amplifier) |
Typical range -20 dBm to 0dBm |
| RF Input Drive for AGC |
Recommended 0 dBm for the best
operation |
| Input Drive Source(amplifier) |
Signal or function
generator, analog computer input capable of up to 2 Vp-p
@ 50 Ohm |
- Input and Output Impedance
|
50 Ohm |
| Input VSWR |
1.2:1 max |
| Output VSWR |
3:1 max |
| Output VSWR Protection |
65W max reflected
power limit. Automatic, limits typically within 0.5 ms
after reverse power reaches 65W or power amplifier current
preset limit. |
Harmonic level @ 100W
|
Better than - 40 dBc for 2-nd
harmonic, any other > -45 dBc |
| Spurious Output |
- 76 dBm equivalent noise level
generated by internal circuits |
| Output Blanking |
For pulsed applications,
T&C amplifiers and generators offer blanking of the
output signal for minimum noise RF spectrum |
| Mismatch Power Output |
Forward Power reference
to rating
1:1:1 VSWR, up to 120W,
2:1 load: 120W FWD, 65W LOAD
3:1 load: 60w fwd, 38W LOAD
9:1 load: 32W FWD, 12W LOAD |
| Dynamic Power Range |
0 to 100W, settings
within +/- 2W |
| RF Output Settings |
-Front Panel EDITOR
-RS 232 port from GUI
-hardware port 1V=100W scale |
| Pulse Specifications |
Pulse Width: 1
to 500 usec
Period: 1 to 50 milliseconds |
| SWEEP Operation |
13.3 to 13.8 MHz.
Min time 10ms, max 10s.
Settings and activation from GUI only |
| Power Margin |
28% |
| RF Power Control |
Front Panel or
REmote Power Control via Hardware Port SubD-25 or RS232
SubD-9 |
| External Communication |
SubD 25 Analog
and Digital I/O.
Port Power scale 1V=100W. Rear Panel |
| RF Input
/ Output Connectors |
INPUT BNC Female
OUTPUT N Female
Rear Panel
|
| AC Power
Source |
100 - 240 VAC, +/-10%,
47 - 63 Hz,
broad input voltage with no adjustment required. |
| AC Power connection |
IEC Standard Power
Entry followed by RFI filter. Filter range 0.1 to 30 MHz
min. |
| Cooling |
Forced air, temperature controlled
heatsink temperature monitored for equipment safety at
70C limit. |
| Case |
Designed to meet EMI and RFI
shielding requirements still chassis, blackened. Front
Panel: T&C off-white |
| Dimensions (with hardware) |
H135mm x W211mm x L445mm ( 5.25
H x 8.3 x 17.5) |
| Weight |
10.5 kg, 23.5 lbs. |
| Mounting |
Half Rack, 3U high.
Optional: Rack Mount Kit, Adapter Kit, Coupling Screws. |
| Operating
Temperature |
Temperature: 10°
to 35° C ambient air |