AG 0313 RF Generator

AG 0313 has 300 Watts RF Power at 13.56 MHz for Industrial and Laboratory Applications.

PDF DOWNLOADS:

AG 0313 RF Generator
 
 

STANDARD FEATURES

  • 13.3 MHz to 13.8 MHz up to greater than 300 Watts
  • Low harmonic level at 300W h2£ -40 dBc, h3 and higher < -55 dBc
  • Digital Meter, measures forward, reflected, and load power simultaneously.
  • Front Panel Control of Generator and Amplifier functions.
  • Data acquisition: Status Monitoring & Power Measurement at Analog Port
  • Optional RS232 communication: Full Control Of Generator/Amplifier Functions
  • AGC Power Leveling: Output Power Control to better than ± 3 W of set value.
  • Burst & Sweeping with custom defined settings.

SPECIFICATIONS

DESCRIPTION RANGE/CHARACTERISTIC
Class of Operation Class B
Frequency of Operation / Frequency Stability
13.56 MHz default, adjustable from 13.3 MHz to 13.8 MHz/ 0.005%
RF Power Output >300 Watts into 50 Ohm
Gain(as amplifier) in MGC/Burst Mode 54 dB @ 100W +/-1dB (0dBm IN Drive)
RF Input Drive(as amplifier) Typical range -20 dBm to 5 dBm
RF Input Drive for AGC Recommended +1 to +3 dBm for the best operation
Input Drive Source(amplifier) Signal or function generator, analog computer input capable of up to 1 Vp-p @ 50 Ohm
Input and Output Impedance
50 Ohm
Input VSWR 1.2:1 max
Output VSWR 3:1 max
Output VSWR Protection 75W max reflected power limit. Automatic, limits typically within 0.5 ms after reverse power reaches 75W or power amplifier current preset limit.
Harmonic level @ 300W
Better than - 40 dBc for 2-nd harmonic, any other > -50 dBc
Spurious Output - 76 dBm equivalent noise level generated by internal circuits
Output Blanking For pulsed applications, T&C amplifiers and generators offer blanking of the output signal for minimum noise RF spectrum
Mismatch Power Output Forward Power reference to rating
1:1:1 VSWR (50ohm), up to 350W,
2:1 load: 350W FWD, 185W LOAD
3:1 load: 180w fwd, 115W LOAD
9:1 load: 115W FWD, 43W LOAD
Dynamic Power Range 0 to 350W, settings within +/- 2W
RF Output Settings -Front Panel EDITOR
-RS 232 port from GUI
-hardware port 1V=100W scale
Pulse Specifications Pulse Width: 1 to 500 usec
Period: 1 to 50 milliseconds
SWEEP Operation 13.3 to 13.8 MHz. Min time 10ms, max 10s.
Settings and activation from GUI only
Power Margin 28%
RF Power Control Front Panel or REmote Power Control via Hardware Port SubD-25 or RS232 SubD-9
External Communication SubD 25 Analog and Digital I/O.
Port Power scale 1V=100W. Rear Panel
RF Input / Output Connectors

INPUT BNC Female
OUTPUT N Female
Rear Panel

AC Power Source 100 - 240 VAC, +/-10%, 47 - 63 Hz,
broad input voltage with no adjustment required.
AC Power connection IEC Standard Power Entry followed by RFI filter. Filter range 0.1 to 30 MHz min.
Cooling Forced air, temperature controlled heatsink temperature monitored for equipment safety at 70C limit.
Case Designed to meet EMI and RFI shielding requirements still chassis, blackened. Front Panel: T&C off-white
Dimensions (with hardware) H135mm x W211mm x L445mm ( 5.25” H x 8.3” x 17.5)
Weight 10.5 kg, 23.5 lbs.
Mounting Half Rack, 3U high. Optional: Rack Mount Kit, Adapter Kit, Coupling Screws.
Operating Temperature Temperature: 10° to 35° C ambient air

 

 
About T&C | Plasma Systems | AG Amplifiers | ULTRA Amplifiers LA Amplifiers HV GenerarorsContact | Careers
 RF SystemsRF Specials | Application Notes | Software Downloads | Doing Business With Us | Site map

hosting, serwer agencja reklamowa, web design, flash
PolskaNoc.pl Wroc³aw Poznań Warszawa Eragon wino