| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class B |
| Frequency of Operation
/ Frequency Stability |
13.56 MHz, 0.005%
|
| RF Power Output |
>600 Watts into
50 Ohm |
| Gain(as amplifier)
in MGC/Burst Mode |
57 dB @ 100W +/-1dB
(0dBm IN Drive) |
| RF Input Drive(as amplifier) |
Typical range -20 dBm to 0 dBm |
| RF Input Drive for AGC |
Recommended +1 to +3 dBm for
the best operation |
| Input Drive Source(amplifier) |
Signal or function
generator, analog computer input capable of up to 2Vp-p
@ 50 Ohm |
- Input and Output Impedance
|
50 Ohm |
| Input VSWR |
1.2:1 max |
| Output VSWR |
3:1 max |
| Output VSWR Protection |
80W max reflected
power limit. Automatic, limits typically within 0.5 ms
after reverse power reaches 80W or power amplifier current
preset limit. |
Harmonic level
|
@300W: Better than -50 dBc
for 2nd harmonic, h3 and higher > -55 dBc
@550W: Better than -50 dBc for 2nd harmonic, h3 and higher
>-55 dBc |
| Spurious Output |
- 76 dBm equivalent noise level
generated by internal circuits |
| Output Blanking |
For pulsed applications,
T&C amplifiers and generators offer blanking of the
output signal for minimum noise RF spectrum |
| Mismatch Power
Output |
Forward Power reference
to rating
1:1:1 VSWR (50ohm), up to 650W,
2:1VSWR (25ohm), 210 W min.
3:1 VSWR (15ohm), 145 W min. |
| Dynamic Power Range |
0 to 600W, settings
within +/- 3W |
| RF Output Settings |
-Front Panel EDITOR
-RS 232, RS 485 and USB port from GUI
-hardware port 1V=100W, 5V=600W, 10V=600W scales user
defined on hardware port |
| Burst Operation |
User settings via
GUI or own Width and Duty Cycle over hardware port |
| SWEEP
Operation |
not availble |
| Power Margin |
50% |
| RF Power Control |
Front Panel or
Remote Power Control via Hardware Port SubD-25, RS232
SubD-9, RS 485 and USB ports |
| External Communication |
SubD 25 Analog
and Digital I/Os.
Rear Panel. |
| RF Input
/ Output Connectors |
INPUT BNC Female
OUTPUT N Female
Rear Panel
|
| AC Power
Source |
100 - 120, 200 -
240 VAC, +/-10%, 47 - 63 Hz,
broad input voltage with no adjustment required.
Max: 11A |
| AC Power connection |
IEC Standard Power
Entry followed by RFI filter. Filter range 0.1 to 30 MHz
min. |
| Cooling |
Forced air, temperature controlled
heatsink temperature monitored for equipment safety at
70C limit. |
| Case |
Designed to meet EMI and RFI
shielding requirements aluminum natural finish. Front
Panel: plastic overlay with membrane switches. |
| Dimensions (with hardware) |
H135mm x W211mm x L445mm ( 5.25
H x 8.3 x 17.5) |
| Weight |
9 kg, 20 lbs. |
| Mounting |
Half Rack, 3U high.
Optional: Rack Mount Kit, Adapter Kit, Coupling Screws. |
| Operating
Temperature |
Temperature: 0°
to 40° C ambient air |