| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class B |
| Frequency of Operation
/ Frequency Stability |
100 kHz to 500 kHz
|
| RF Power Output |
50 Ohm load:
400W for 100 to 500 kHz, Up to 550W for 200 to 450 kHz
Any load: up to 200W, continuous operation |
| Mismatch Power Output |
Continuous Load
Power at 20C:
2:1 VSWR (25 Ohm) 210W minimum
3:1 VSWR (15 Ohm) 145W minimum
Limited by heat protection circuit!
Burst and Pulse mode Load Power:
3:1 VSWR, 300W minimum
Limited by Reverse Power Limitter! |
| RF Input Drive for AGC |
Recommended -3 to 0 dBm for
+/-0.5 dB gain flatness |
| Input Drive Source |
Signal or function
generator, analog computer input capable of 1 Vp-p @ 50
Ohm
Input range: -30 to 0dBm typical, +5dBm maximum |
| Internal RF Source |
DDS oscillator:
100 kHz to 500 kHz. 1 kHz resolution |
- Input and Output Impedance
|
50 Ohm |
| Input VSWR |
2:1 max |
| Output VSWR |
3:1 max |
| Output VSWR Protection |
80W max reflected
power limit for Load Impedance > 50 Ohm. Current level
protection for Load Impedance < 50 Ohm. |
Harmonic level @ 500W
|
450 kHz: - 40 dBc or
better for any harmonic (built-in output filter),
200 kHz: -20 dBc or better for any harmonic (no
filter effect). |
| Spurious Output |
- 45 dBc |
| Output Blanking |
For pulsed applications,
T&C amplifiers and generators offer blanking of the
output signal for minimum noise RF spectrum |
| BURST Operation |
Pulse range: 1
to 550W
Period: 1 to 50 miliseconds
User settings via GUI and RS232 |
| BURST - external |
DC to > 200
kHz. User defined
BURST scheme via SubD-25.
See analog port description for more details. |
| SWEEP operation |
100 to 500 kHz.
Min time 10 ms, Max 10s. Settings and activation from
GUI only. |
| Output Settings &
Control |
- Front Panel EDITOR
and function
switches for manual control,
- RS232 port for GUI or other
computer communication. Rear
Panel.
- SubD 25 Analog and Digital I/O .
Port power scale 1V=100W. Rear Panel |
| Pulse Specifications |
Pulse Width from
2 mu to continues, user defined |
| RF Connectors
= |
BNC Female: Back Panel
|
| Acoustic Level
= |
45dBa @ Max Fan
Speed @ temp. |
| AC Power Connection
= |
IEC Standard Power
Entry followed by RFI filter. Filter range 0.1 to 30 MHz
min. |
| AC Power Source = |
200 - 240 VAC, 50/60 Hz, +/-
10% |
| AC Input Current (RMS) = |
Max: 11.5 A |
| Cooling = |
Forced air, temperature controlled,
heatsink temperature monitored via RS232 GUI interface |
| Dimensions (with hardware) |
H135mm x W211mm x L445mm ( 5.25
H x 8.3 x 17.5 ) |
| Weight |
14.8 kg, 32.5 lbs. |
| Mounting |
Half Rack, 3U high.
Optional: Rack Mount Kit, Adapter Kit, Coupling Screws. |
| Environmental conditions |
Temperature: 10°
to 40° C ambient air
Humidity: 80%
Equipment intended for ISM applications in laboratory
and light industrial environment. |