| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class C/D |
| Frequency of Operation
/ Frequency Stability |
13.56 MHz default / 0.005%
|
| RF Power Output |
1200 Watts into
50 Ohm |
| Output(as amplifier)
in MGC/Burst Mode |
0 dBm IN, 10V CTL
IN pin 5 1000W ±10W |
| RF Input Drive for AGC |
Recommended +0 to +1.5 dBm for
the best operation |
| Input Drive Source(amplifier) |
Signal or function
generator, analog computer input capable of up to 2 Vp-p
@ 50 Ohm |
| Internal RF Source |
Crystal oscillator
at 13.56 MHz |
- Input and Output Impedance
|
50 Ohm |
| Input VSWR |
1.2:1 max |
| Output VSWR |
3:1 max |
| Output VSWR Protection |
250 W max reflected
power limit. Automatic foldback limit with [W] level of
protection depending on actual VSWR of a load connected. |
Harmonic level @ 1150W
|
Better than - 50 dBc for 2-nd
harmonic, any other > -55 dBc |
| Spurious Output |
- 55 dBm equivalent noise level
generated by internal circuits |
| Output Blanking |
T&C amplifiers
and generators offer blanking of the output signal for
minimum noise RF spectrum |
| Dynamic Power Range |
1 to 1200W, settings
within +/- 12W |
| Output Settings &
Control (Communications) |
SubD 25 Analog
and Digital I/O.
Port Power scale 5V and 10V user selectable. Rear Panel |
| RF Burst (Pulse)
Specifications |
Pulse Width from
2 us to continues, user defined. Rising and falling edges
better than 1us. |
| Power Margin |
>130% (Note!
end stage Pdc margin @ 25C water temp.) |
| RF Input / Output connectors |
INPUT BNC Female
OUTPUT N Female
Rear Panel
|
| AC Power
Source |
200 - 240 VAC, +/-10%,
47 - 63 Hz,
broad input voltage with no adjustment required. |
| AC Power connection |
Permanently attached
line cord with plug (meeting safety requirements of the
region where equipment will be operating). PFC of 95%
at 230 VAC. |
| AC Circuit Protection |
Back Panel Thermal Circuit Breaker,
12A |
| AC Input Current (RMS) |
I<10A @ 220V. Unit features
AC Input PFC ! |
| Cooling |
Water cooled and forced air, heatsink temperature monitored
for equipment safety at 70C limit.
Water flow >1 GPM (4 LPM) and temperature 20C-25
C.
|
| Dimensions (with hardware) |
H135mm x W212mm x L482mm ( 5.25
H x8.3 x 19 ) |
| Weight |
10 kg, 21 lbs. |
| Mounting |
1/2 Rack, 3U high.
Optional: Rack Mount Kit, Adapter Kit, Coupling Screws. |
| Environmental conditions |
Temperature: 10°
to 40° C ambient air
Humidity: 80%
Equipment intended for ISM applications in laboratory
and light industrial environment. |
| Case |
Designed to meet EMI and RFI shielding requirements
aluminum natural finish.
Front Panel: T&C off white for 1213W
(basic) and 1213W D-Comm models. Plastic overlay
with membrane switches for AG 1213W models.
|