| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class B |
| Frequency of
Operation |
20 kHz to 14 MHz
-amplifier
20 kHz to 6 MHz -generator |
| RF Power Output |
50 Ohm load:
Up to 200W from 20 kHz to 8 MHz,
Up to 300W from 20 kHz to 4 MHz, <125W to 14 MHz, Pulse
and low duty cycle
Any load:
Up to 150W continuous operation |
| Gain |
55 dB @ 300W /0.5
MHz +/-1 dB |
| RF Power Input
Drive |
Typical range -20 dBm to 5 dBm
max |
| RF Power Input
Drive for AGC |
Recommended -5
dBm to 0 dBm for +/-0.5 dB gain flatness |
| Input Drive
Source |
Signal or function
generator, analog computer output capable of up to 1 Vp-p
@ 50 Ohm (+5dBm) |
| Internal RF
Source |
DDS oscillator:
20 kHz to 6MHz, 1 kHz resolution |
-
Input and Output Impedance
|
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR |
| Output VSWR
Protection |
70 W max. reflected
power limit |
| Harmonic level
@ 250 W |
Better then - 12 dBc for 3rd
harmonic,
any other > -18 dBc |
| Spurious Output |
- 26 dBm equivalent noise level
generated by internal circuits |
| RF Output Settings
& Control |
-Front Panel EDITOR
and function switches for manual control,
-RS232 port for GUI or other computer communication. Rear
Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W.
Rear Panel. |
| BURST |
Internal settings:
Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description
for more details. |
| SWEEP Operation |
0.02 to 6 MHz.
Min time 10 ms, max 10s. Settings and activation from
GUI only |
| Output Blanking |
For pulsed applications,
T&C amplifiers and generators may offer blanking of
the output signal for minimum RF spectrum noise. Less
than 1 mu Rise/Fall time. |
| RF Connectors |
BNC Female: Back
Panel |
| AC Power Source |
100-120 VAC, 200-240
VAC, +/- 10%, 47-63 Hz, No adjustment required. |
| AC Power Connection |
IEC Standared Power Entry followed
by RFI filter. Filter range 0.1 to 30 MHz min |
| AC Circuit Protection |
Internally fused on the main
DC Power Supply, 15A |
| AC Input Current
(RMS) |
RF Out nominal 150W: I<7A
@ 115V/ I <3A @ 220V
RF Out max 300W: I<10A @ 115V/ I <4.2A @
220V |
| Cooling |
Forced air, temperature controlled,
heatsink temperature monitored via RS232 GUI interface. |
| Acoustic level |
45 dBa @ Max Fan Speed @ temp. |
| Case |
Designed to meet EMI and RFI
shielding requirements AL chassis, yellow conductive finish.
Front Panel: T&C off-white. Cover: T&C black. |
| Dimensions (with
hardware) |
(H 135 x W 254 x L 385) mm (
5.25 x 10 x 15 )
Optional Half Rack, 3U High. |
| Weight |
12 kg, 26 lbs. |
| Mounting |
Stand alone unit.
(Optional Rack Mount Kit) |
| Environmental Conditions |
Temp: 10°C to 35°C
Humidity: 80% |