| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class B |
| Frequency of
Operation |
50 kHz to 500 kHz |
| RF Power Output |
600W from 50 kHz
to 500 kHz of continuous output into any load.
Up to 1200W max from 50 kHz to 500 kHz, 50 Ohm load only,
20C,
Pulsing and low duty cycle only! |
| Gain |
62 dB @ 1200W /500
kHz +/-1.5 dB 50 kHz to 500 kHz (600W Out) |
| RF Power Input
Drive |
Typical range -20 dBm to 0 dBm,
+5 dBm max |
| RF Power Input
Drive for AGC |
Recommended -3
dBm to 0 dBm for +/-0.3 dB gain flatness |
| Input Drive
Source |
Signal or function
generator, analog computer output capable of up to 1 Vp-p
@ 50 Ohm (+5dBm) |
| Internal RF
Source |
DDS oscillator:
20 kHz to 2 MHz, 1 kHz resolution |
-
Input and Output Impedance
|
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR |
| Output VSWR
Protection |
160 W max. reflected
power limit |
| Harmonic level
@ 750 W |
Better then -19 dBc for any
harmonic |
| Spurious Output |
- 26 dBm equivalent noise level
generated by internal circuits |
| RF Output Settings
& Control |
-Front Panel EDITOR
and function switches for manual control
-RS232 port for GUI or other computer communication. Rear
Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W.
Rear Panel. |
| RF Power Meter
accuracy |
+/- 3% typical |
| Output Blanking |
For pulsed applications,
T&C amplifiers and generators may offer blanking of
the output signal for minimum RF spectrum noise. Less
than 1 mu Rise/Fall time. |
| BURST |
Internal settings:
Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description
for more details. |
| SWEEP Operation |
50 kHz to 500 kHz.
Min time 10 ms, max 10s. Settings and activation from
GUI only |
| RF Connectors |
INPUT BNC Female
OUTPUT N Female
Rear Panel |
| AC Power Connection |
Non-detachable power cord anchored
with compression bushing followed by RFI filter. Back
Panel. |
| AC Circuit Protection |
20 A, double pole switch/circuit
breaker on the Front Panel. Internally fused on the main
DC Power Supply, 15A |
| AC Input Current
(RMS) |
100-120 V ac, 50-60 Hz, 22A
200-240 V ac, 50-60 Hz, 12A |
| Cooling |
Forced air, temperature controlled,
heatsink temperature monitored via RS232 GUI interface. |
| Acoustic level |
45 dBa @ Max Fan Speed @ temp. |
| Case |
Designed to meet EMI and RFI
shielding requirements AL chassis, yellow conductive finish.
Front Panel: T&C off-white. Cover: T&C black. |
| Dimensions (with
hardware) |
(H 178 x W 362 x L584) mm (7
x 14.25 x 23 ) |
| Weight |
25 kg, 54 lbs. |
| Mounting |
Table top stand
alone unit. (Optional Rack Mount Kit) |
| Environmental Conditions |
Temp: 10°C to 30°C
Humidity: 80% |