AG 1012-13 LF POWER AMPLIFIER

AG 1012-13 a Classical Design offers up to 1250 Watts RF Power at 13.56 MHz for Industrial, Laboratory and Drop-in Replacement Markets.AG 1012 LF Power Amplifier

PDF DOWNLOADS:

 
 

STANDARD FEATURES

  • 13.56 MHz
  • Output of 1250 Watts h3.-45 dBc
  • Digital Meter, measures forward and reflected power
  • Front Panel Control of Generator and Amplifier functions
  • Data acquisition: Status Monitoring &Power Measurement at Analog Port
  • Features 25 pin Accessory Connector. Additional interface standards available upon request for direct replacement in established systems
  • RS232 Communication: Full Control Of Amplifier & Generator Functions
  • AGC or Power Leveling: Gain Control to better than ±0.5 dB
  • Pulse and Sweep of RF internal signal

SPECIFICATIONS

DESCRIPTION RANGE/CHARACTERISTIC
Class of Operation Class C (bipolar end stages reflecting technological drop-in replacements)
Frequency of Operation 13.56 MHz
RF Power Output Up to 1250 W max, 50 Ohm load Other loads within FWD and REV power limits.
Gain 62 dB @ 1200W +/-0.5 MHz
RF Power Input Drive Typical range -20 dBm to 0 dBm, +5 dBm max
RF Power Input Drive for AGC Recommended -3 dBm to 0 dBm for +/-0.3 dB gain flatness
Input Drive Source Signal or function generator, analog computer output capable of up to 1 Vp-p @ 50 Ohm (+5dBm)
Internal RF Source DDS oscillator: 20 kHz to 6 MHz, 1 kHz resolution
Input and Output Impedance
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR
Output VSWR Protection 200 W max. reflected power limit
Harmonic level @ 750 W Better then - 45 dBc for any harmonic
Spurious Output -50 dBc
RF Output Settings & Control -Front Panel EDITOR and function switches for manual control,
-RS232 port for GUI or other computer communication. Rear Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W. Rear Panel.
RF Power Meter accuracy +/-3% typical
Output Blanking For pulsed applications, T&C amplifiers and generators may offer blanking of the output signal for minimum RF spectrum noise. Less than 1 mu Rise/Fall time.
BURST Internal settings: Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description for more details.
SWEEP Operation 13.56 MHz +/-0.2MHz, in time 10 ms, max 10s. Settings and activation from GUI only
RF Connectors INPUT BNC Female
OUTPUT N Female
Analog Interface 25 pin; RS 232 Interface
AC Power Connection Non-detachable power cord anchored with compression bushing followed by RFI filter. Back Panel
AC Circuit Protection Internally fused on the main DC Power Supply, 15A
AC Input Current (RMS) 120 V ac, 50-60 Hz, 20 A
200 - 240 V ac, 50-60 Hz, 12 A
Product Features Power Factor Correction (PFC)
Cooling Forced air, temperature controlled, heatsink temperature monitored via RS232 GUI interface.
Acoustic level 45 dBa @ Max Fan Speed @ temp.
Case Designed to meet EMI and RFI shielding requirements AL chassis, yellow conductive finish. Front Panel: T&C off-white. Cover: T&C black.
Dimensions (with hardware) (H 178 x W 363 x L 388) mm (7” x 14.25” x 15.25” )
Optional Half Rack, 3U High.
Weight 25 kg, 54 lbs.
Mounting Stand alone unit. (Optional Rack Mount Kit)
Environmental Conditions Temp: 10°C to 35°C
Humidity: 80%
 
         