| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class B to 1000
Watts |
| Frequency of
Operation |
20 kHz to 6 MHz |
| RF Power Output |
600W from 0.02
HHz to 6 MHz of continuous ouput into any load.
Up to 1000W max from 0.4 MHz to 5 MHz, 50 Ohm load only,
20C
Pulsing and low duty cycle only! |
| Gain |
62 dB @ 200W /0.5
MHz +/-1 dB 20 kHz to 60 MHz (200W Out) |
| RF Power Input
Drive |
Typical range -20 dBm to 0 dBm,
+5 dBm max |
| RF Power Input
Drive for AGC |
Recommended -3
dBm to 0 dBm for +/-0.3 dB gain flatness |
| Input Drive
Source |
Signal or function
generator, analog computer output capable of up to 1 Vp-p
@ 50 Ohm (+5dBm) |
| Internal RF
Source |
DDS oscillator:
20 kHz to 6 MHz, 1 kHz resolution |
-
Input and Output Impedance
|
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR |
| Output VSWR
Protection |
160 W max. reflected
power limit |
| Harmonic level
@ 750 W |
Better then - 15 dBc for 3rd
harmonic,
any other > -20 dBc |
| Spurious Output |
- 26 dBm equivalent noise level
generated by internal circuits |
| RF Output Settings
& Control |
-Front Panel EDITOR
and function switches for manual control,
-RS232 port for GUI or other computer communication. Rear
Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W.
Rear Panel. |
| RF Power Meter
accuracy |
+/-3% typical |
| Output Blanking |
For pulsed applications,
T&C amplifiers and generators may offer blanking of
the output signal for minimum RF spectrum noise. Less
than 1 mu Rise/Fall time. |
| BURST |
Internal settings:
Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description
for more details. |
| SWEEP Operation |
0.02 to 6 MHz.
Min time 10 ms, max 10s. Settings and activation from
GUI only |
| RF Connectors |
INPUT BNC Female
OUTPUT N Female
Rear Panel |
| AC Power Source |
200-240 VAC, +/-
10%, 47-63 Hz |
| AC Power Connection |
IEC Standared Power Entry followed
by RFI filter. Filter range 0.1 to 30 MHz min |
| AC Circuit Protection |
Internally fused on the main
DC Power Supply, 15A |
| AC Input Current
(RMS) |
RF Out nominal 600W: I<8A
@ 220V
RF Out max 1000W: I<13A @ 220V |
| Cooling |
Forced air, temperature controlled,
heatsink temperature monitored via RS232 GUI interface. |
| Acoustic level |
45 dBa @ Max Fan Speed @ temp. |
| Case |
Designed to meet EMI and RFI
shielding requirements AL chassis, yellow conductive finish.
Front Panel: T&C off-white. Cover: T&C black. |
| Dimensions (with
hardware) |
(H 178 x W 363 x L 388) mm (7
x 14.25 x 15.25 )
Optional Half Rack, 3U High. |
| Weight |
25 kg, 54 lbs. |
| Mounting |
Stand alone unit.
(Optional Rack Mount Kit) |
| Environmental Conditions |
Temp: 10°C to 35°C
Humidity: 80% |