| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class "A" |
| Frequency of
Operation |
10 kHz to 6 MHz |
| RF Power Output |
50 Ohm load:
Up to 1000W for 20 kHz to 2 MHz
Up to 750W for 10kHz to 4 MHz
Up to 400W for 10 MHz to 6 MHz
Pulse and low duty cycle!
Any load:
Up to 400W, continuous operation |
| Gain |
60 dB @ 1000W /
1MHz
+/-1.5 dB 20 kHz to 2 MHz
-2 dB drop: 10kHz to 20kHz and 2 MHz to 6MHz |
| RF Power Input
Drive |
Typical range -30 dBm to 0 dBm,
+5 dBm max |
| RF Power Input
Drive for AGC |
Recommended -5
dBm to 0 dBm for +/-0.5 dB gain flatness |
| Input Drive
Source |
Signal or function
generator, analog computer output capable of up to 1 Vp-p
@ 50 Ohm (+5dBm)
Input range: -30 to 0 dBm typical, +5 dBm max |
| Internal RF
Source |
DDS oscillator:
10 kHz to 6 MHz, 1 kHz resolution |
-
Input and Output Impedance
|
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR |
| Output VSWR
Protection |
250 W max. reflected
power limit for load impedance > 50 Ohm. Current level
protection for Load Impedance < 50 Ohm. |
| Harmonic level
|
@ 400 W: Better then
- 20 dBc for 3rd harmonic,
any other > -30 dBc
@ 950W: -14 dBc |
| Spurious Output |
- 26 dBm equivalent noise level
generated by internal circuits |
| RF Output Settings
& Control |
-Front Panel EDITOR
and function switches for manual control,
-RS232 port for GUI or other computer communication. Rear
Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W.
Rear Panel. |
| Output Blanking |
For pulsed applications,
T&C amplifiers and generators may offer blanking of
the output signal for minimum RF spectrum noise. |
| BURST |
Internal settings:
Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description
for more details. |
| SWEEP Operation |
0.01 to 6MHz. Min
time 10 ms, max 10s. Settings and activation from GUI
only |
| RF Connectors |
BNC Female: RF
In
"N type" Female: RF Out |
| AC Power Source |
200-240 VAC, +/-
10%, 47-63 Hz, No adjustment required. |
| AC Power Connection |
See manual for details |
| AC Input Current
(RMS) |
RF Out nominal 400W: I<10A
@ 220V
RF Out max 1000W: I<16A @ 220V |
| Cooling |
Forced air, temperature controlled,
heatsink temperature monitored via RS232 GUI interface. |
| Acoustic level |
45 dBa @ Max Fan Speed @ temp. |
| Case |
Designed to meet EMI and RFI
shielding requirements AL chassis, yellow conductive finish.
Front Panel: T&C off-white. Cover: T&C black. |
| Dimensions (with
hardware) |
(H 405 x W 520 x L 470) mm (
16 x 20.5 x 18.5 )
Optional Half Rack, 3U High. |
| Weight |
59 kg, 130 lbs. |
| Mounting |
Stand alone unit.
(Optional Rack Mount Kit) |
| Environmental Conditions |
Temp: 10°C to 35°C
Humidity: 80% |