| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class B |
| Frequency of
Operation |
20 kHz to 6 MHz
|
| RF Power Output |
400W for 20 kHz
to 6 MHz
500W for 100 kHz to 5 MHz
600W for 150 kHz to 4 MHz |
| Mismatch Power
Output |
Continous Load
Power at 20C:
2:1 VSWR (25 Ohm) 210W min
3:1 VSWR (15 Ohm) 145W min
Limited by Reverse Power Limitter! |
| Gain |
57 dB @ 500W /0.75
MHz +/-1.5 dB 20 kHz to 6 MHz |
| RF Power Input
Drive for AGC |
Recommended -5
dBm to 0 dBm for +/-0.5 dB gain flatness |
| Input Drive
Source |
Signal or function
generator, analog computer output capable of up to 1 Vp-p
@ 50 Ohm. Input range: -30 to 0 dBm typical, +5 dBm max |
-
Input and Output Impedance
|
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR |
| Output VSWR
Protection |
80 W max. reflected
power limit for Load Impedance > 50 Ohm. Current level
protection for Load Impedance < 50 Ohm. |
| Harmonic level
@ 550 W |
Better then - 14 dBc for 3rd
harmonic,
any other > -30 dBc |
| Spurious Output |
- 76 dBm equivalent noise level
generated by internal circuits approx. -20 dBm coninuous
level noise present at the amplifier output in 70 kHz
to 150 kHz band |
| RF Output Settings
& Control |
-Front Panel EDITOR
and function switches for manual control,
-RS232 port for GUI or other computer communication. Rear
Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W.
Rear Panel. |
| BURST |
Internal settings:
Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description
for more details. |
| SWEEP Operation |
0.02 to 6 MHz.
Min time 10 ms, max 10s. Settings and activation from
GUI only |
| Output Blanking |
For pulsed applications,
T&C amplifiers and generators may offer blanking of
the output signal for minimum RF spectrum noise. |
| RF Connectors |
BNC Female: Back
Panel |
| AC Power Source |
200-240 VAC, +/-
10%, 47-63 Hz, No adjustment required. Max: 11.5A |
| AC Power Connection |
IEC Standared Power Entry followed
by RFI filter. Filter range 0.1 to 30 MHz min |
| Cooling |
Forced air, temperature controlled,
heatsink temperature monitored via RS232 GUI interface. |
| Case |
Designed to meet EMI and RFI
shielding requirements AL chassis, yellow conductive finish.
Front Panel: T&C off-white. Cover: T&C black. |
| Dimensions (with
hardware) |
(H 135 x W 254 x L 385) mm (
5.25 x 10 x 15 )
Optional Half Rack, 3U High. |
| Weight |
12 kg, 26 lbs. |
| Mounting |
Stand alone unit.
(Optional Rack Mount Kit) |
| Environmental Conditions |
Temp: 10°C to 35°C
Humidity: 80% |