| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class A to 200
Watts |
| Frequency of
Operation |
10 kHz to 10 MHz |
| RF Power Output |
200 W from 0.01
MHz to 10 MHz of continuous linear output into any load.
Up to 500W max from 0.2 MHz to 4 MHz, 50 Ohm load only.
Pulsing and low duty cycle only! |
| Gain |
53 dB @ 200W / 1MHz
+/-1 dB 10 kHz to 10 MHz (50W Out) |
| RF Power Input
Drive |
Typical range -20 dBm to 0 dBm,
+5 dBm max |
| RF Power Input
Drive for AGC |
Recommended -3
dBm to 0 dBm for +/-0.3 dB gain flatness |
| Input Drive
Source |
Signal or function
generator, analog computer output capable of up to 1 Vp-p
@ 50 Ohm (+5dBm) |
| Internal RF
Source |
DDS oscillator:
10 kHz to 10 MHz, 1 kHz resolution |
-
Input and Output Impedance
|
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR |
| Output VSWR
Protection |
100 W max. reflected
power limit |
| Harmonic level
|
@ 200 W: Better then
- 20 dBc for 3rd harmonic,
any other > -28 dBc
@ 250W: -15 dBc |
| Spurious Output |
- 26 dBm equivalent noise level
generated by internal circuits |
| RF Output Settings
& Control |
-Front Panel EDITOR
and function switches for manual control,
-RS232 port for GUI or other computer communication. Rear
Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W.
Rear Panel. |
| Output Blanking |
For pulsed applications,
T&C amplifiers and generators may offer blanking of
the output signal for minimum RF spectrum noise. Less
than 1 mu Rise/Fall time |
| RF Power Meter
accuracy |
+/- 3% typical |
| BURST |
Internal settings:
Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description
for more details. |
| SWEEP Operation |
0.01 to 10MHz.
Min time 10 ms, max 10s. Settings and activation from
GUI only |
| RF Connectors |
INPUT BNC Female
OUTPUT N Female
Rear Panel |
| AC Power Source |
200-240 VAC, +/-
10%, 47-63 Hz, No adjustment required. |
| AC Power Connection |
IEC Standared Power Entry followed
by RFI filter. Filter range 0.1 to 30 MHz min |
| AC Circuit Protection |
Internally fused on the main
DC Power Supply, 15A |
| AC Input Current
(RMS) |
15A max |
| Cooling |
Forced air, temperature controlled,
heatsink temperature monitored via RS232 GUI interface. |
| Acoustic level |
45 dBa @ Max Fan Speed @ temp. |
| Case |
Designed to meet EMI and RFI
shielding requirements AL chassis, yellow conductive finish.
Front Panel: T&C off-white. Cover: T&C black. |
| Dimensions (with
hardware) |
(H 178 x W 363 x L 388) mm (
7 x 14.25 x 15.25 )
Optional Half Rack, 3U High. |
| Weight |
25 kg, 54 lbs. |
| Mounting |
Stand alone unit.
(Optional Rack Mount Kit) |
| Environmental Conditions |
Temp: 10°C to 35°C
Humidity: 80% |