AG 1021

LF/HF LINEAR AMPLIFIER AND POWER GENERATOR

AG 1021 is a low frequency air-cooled amplifier with built-in DDS oscillator. It is suitable for ultrasonic, laser modulation, RFI/EMI, plasma and general industry and laboratory applications. AG 1021 LF HF Linear Amplifier Generator

PDF DOWNLOADS:

 
 

STANDARD FEATURES

  • Typical output: P1dB = 53 dB, 300W max into 50 Ohm loads, h3=<-15dBc
  • Linear output: 100W
  • Power Meter: RMS measurement of forward and reflected power.
  • Data acquisition: analog port for status monitoring and power measurement. Compatible with IO-TECH and NATIONAL INSTRUMENT Data Acquisition cards.
  • AGC or power leveling: feature for gain control of ±0.5dB.
  • RS232 communication: full control of all amplifier and generator functions.

SPECIFICATIONS

DESCRIPTION RANGE/CHARACTERISTIC
Class of Operation Class A to 100 Watts
Frequency of Operation 10 kHz to 20 MHz
RF Power Output 100 W from 0.015 MHz to 12 MHz of continuous linear output into any load.
Up to 300W total power margin, 50 Ohm resistive load only, 20C, Pulsing only!
Gain 53 dB @ 100W / 1MHz
+/-1 dB 20 kHz to 14 MHz (100W Out)
RF Power Input Drive Typical range -30 dBm to 0 dBm, +5 dBm max
RF Power Input Drive for AGC Recommended -3 dBm to 0 dBm for +/-0.3 dB gain flatness
Input Drive Source Signal or function generator, analog computer output capable of up to 1 Vp-p @ 50 Ohm (+5dBm)
Internal RF Source DDS oscillator: 10 kHz to 6 MHz, 1 kHz resolution
Input and Output Impedance
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR
Output VSWR Protection 75 W max. reflected power limit
Harmonic level @ 100 W: Better then - 20 dBc for 3rd harmonic,
any other > -30 dBc
@ 250W: -14 dBc
Spurious Output - 26 dBm equivalent noise level generated by internal circuits
RF Output Settings & Control -Front Panel EDITOR and function switches for manual control,
-RS232 port for GUI or other computer communication. Rear Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W. Rear Panel.
Output Blanking For pulsed applications, T&C amplifiers and generators may offer blanking of the output signal for minimum RF spectrum noise. Less than 1 mu Rise/Fall time
RF Power Meter accuracy +/- 3% typical
BURST Internal settings: Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description for more details.
SWEEP Operation 0.01 to 15MHz. Min time 10 ms, max 10s. Settings and activation from GUI only
RF Connectors BNC Female: Front Panel
AC Power Source 100-120 VAC, 200-240 VAC, +/- 10%, 47-63 Hz, No adjustment required.
AC Power Connection IEC Standared Power Entry followed by RFI filter. Filter range 0.1 to 30 MHz min
AC Circuit Protection Internally fused on the main DC Power Supply, 15A
AC Input Current (RMS) RF Out nominal 175W: I<7A @ 115V/ I <3A @ 220V
RF Out max 300W: I<9A @ 115V/ I < 4A @ 220V
Cooling Forced air, temperature controlled, heatsink temperature monitored via RS232 GUI interface.
Acoustic level 45 dBa @ Max Fan Speed @ temp.
Case Designed to meet EMI and RFI shielding requirements AL chassis, yellow conductive finish. Front Panel: T&C off-white. Cover: T&C black.
Dimensions (with hardware) (H 135 x W 254 x L 385) mm ( 5.25” x 10” x 15” )
Optional Half Rack, 3U High.
Weight 12 kg, 26 lbs.
Mounting Stand alone unit. (Optional Rack Mount Kit)
Environmental Conditions Temp: 10°C to 35°C
Humidity: 80%
 
         
  About T&C | Plasma Systems | AG Amplifiers | ULTRA Amplifiers LA Amplifiers HV GenerarorsContact | Careers
 RF SystemsRF Specials | Application Notes | Software Downloads | Doing Business With Us | Site map

hosting, serwer agencja reklamowa, web design, flash