| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
Class "B" |
| Frequency of
Operation |
20 kHz to 1 MHz |
| RF Power Output |
50 Ohm load:
Up to 4000W for 20 kHz to 1MHz,
Up to 2000W for 1 MHz to 2 MHz
Up to 800W for 2 MHz to 3 MHz
Pulse and low duty cycle!
Any load:
Up to 3600W continuous operation |
| Gain |
63 dB @ 4000W /0.5
MHz
+/-1.5 dB 20 kHz to 1 MHz |
| RF Power Input
Drive for AGC |
Recommended -5
dBm to 0 dBm for +/-0.5 dB gain flatness |
| Input Drive
Source |
Signal or function
generator, analog computer output capable of up to 1 Vp-p
@ 50 Ohm (+5dBm)
Input range: -30 to 0 dBm typical, +5 dBm max |
| Internal RF
Source |
DDS oscillator:
20 kHz to 1 MHz, 1 kHz resolution |
-
Input and Output Impedance
|
50 Ohm Input
2:1 MAX INPUT VSWR
3:1 max OUTPUT VSWR |
| Output VSWR
Protection |
600W max reflected
power limit for Load Impedance > 50 Ohm.
Current level protection for Load Impedance < 50 Ohm |
| Harmonic level
@ 1750 W |
Better then - 13 dBc for 3rd
harmonic,
any other > -20 dBc |
| Spurious Output |
- 26 dBm equivalent noise level
generated by internal circuits |
| RF Output Settings
& Control |
-Front Panel EDITOR
and function switches for manual control,
-RS232 port for GUI or other computer communication. Rear
Panel
-SubD 25 Analog and Digital I/O. Port power scale 1V=100W.
Rear Panel. |
| BURST |
Internal settings:
Pulse range: 1 to 500 usec
Period: 1 to 50 milliseconds, User settings via GUI RS232
External settings: DC to >200 kHz. User defined
BURST scheme via SubD-25. See analog port description
for more details. |
| SWEEP Operation |
0.02 to 1 MHz.
Min time 10 ms, max 10s. Settings and activation from
GUI only |
| Output Blanking |
For pulsed applications,
T&C amplifiers and generators may offer blanking of
the output signal for minimum RF spectrum noise. Less
than 1 mu Rise/Fall time. |
| RF Connectors |
BNC Female: RF
In
HN Female: RF Out |
| AC Power Source |
120-240 VAC per
phase/neutral rating, 47-63 Hz, Back panel.
Automatic range switching |
| AC Power Connection |
5 wires 12 AWG Line Cord with
Brown, Black, Black, Blue and Green/Yellow color code.
Local 3 phase, 5 wire connector must be provided for correct
connection power line. |
| AC Input Current
(RMS) |
RF Out nominal 3600W:
I <44A @ 220V
RF Out max 4000W: I <50A @ 220V |
| Cooling |
Forced air, temperature controlled,
heatsink temperature monitored via RS232 GUI interface. |
| Acoustic level |
45 dBa @ Max Fan Speed @ temp. |
| Case |
Designed to meet EMI and RFI
shielding requirements AL chassis, yellow conductive finish.
Front Panel: T&C off-white. Cover: T&C black. |
| Dimensions (with
hardware) |
(H 927 x W 533 x L 520) mm (
36.5 x 21 x 20.5 )
Optional Half Rack, 3U High. |
| Weight |
136 kg, 300 lbs. |
| Mounting |
Stand alone unit.
(Optional Rack Mount Kit) |
| Environmental Conditions |
Temp: 10°C to 35°C
Humidity: 80% |