STANDARD FEATURES
- Simple controls for RF, HV, Ignition and Primary Power
- Easy to use rear panel controls for manual setup.
APPLICATIONS
- Industrial and Laboratory Research
- Reliable and Repeatable control of gas plasma
- Preconditioning of incandescent light bulbs
OPERATION
The AG0201HV-XS can be set for its operation
manually from the back panel.
SPECIFICATIONS
| DESCRIPTION |
RANGE/CHARACTERISTIC |
| GENERATOR |
| Frequency Range |
375 kHz +/- 50 kHz |
| Frequency Stability |
< 1% |
| Power Output |
0 - 100 W |
| Ignition Power |
> 120 W |
| Output Impedance |
Designed for the best power
transfer into high impedance loads |
| Output Protection |
Short and open circuit. Overvoltage
on HV output.
Over temperature ( full range air control) |
| Load Mismatch Tolerance |
Continuous--unit protected
against any output load conditions. |
| High Voltage RF Connection |
48" of high voltage cable
with alligator clips
(Other options available) |
| Line Regulation |
0.5% at full power |
| Harmonic Distortion |
< -40 dBc (w/standard load
@ 80 W FWD, 8 kVp-p) |
| Hum, Noise and Ripple |
< -40 dBc (on standard load
@ 80 W FWD, 8 kVp-p) |
|
CONTROLS/INDICATORS/INTERFACE |
| Front Panel |
RF On/Off Control AC, On/Off
switch OUTPUT Level Adjust, Frequency Adjust. |
| Rear Panel |
Connectors: AC Input, HV RF
Output, Safety Ground (0.25" x 20 stud), and Control
Connector. |
| PRIMARY
POWER |
| Input |
100-120, 200- 240 VAC, +/-10%
; 47-63 Hz single phase. |
| Power Required |
Up to 400 VA @ full power output. |
| Circuit Protection |
Fast acting fuses on Power
Supplies |
| Connector |
IEC Standard Power Entry; CE
approved |
| GENERAL |
| Operating Temperature Range |
32 - 113 F (0 - 45 C) |
| Humidity |
80 % |
| Cooling |
Forced-Air |
| Acoustic Level |
45 dBa @ maximum fan speed
and maximum temperature |
| Dimensions |
5.25" x 10" x 15"
(H 134 x W 254x D 381mm) |
| Weight |
15.5 lbs (7.5 kg) |
|
|