STANDARD FEATURES
- EMI/RFI filter
- MIL-STD and CE approved components
APPLICATIONS
- Communications
- EMC Testing
- General Laboratory Use
OPTIONAL FEATURES
SPECIFICATIONS
| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
A |
| Frequency Range |
Amplifier A:
100 Hz to 1MHz; +/- 2dB, 200 Hz to 800 kHz +/- 1dB
Amplifier B: 1 MHz to 450 MHz, +/- 1.5 dB |
| RF Power Output |
10 W linear for
A and B in mid band |
| Gain |
40 dB, +/- 1.5
dB each |
| RF Power Input
Drive |
-10 dBm to 0 dBm
(1 mW) typical, +5 dBm max |
| Input and Output
Impedance |
50 Ohm |
| Input VSWR |
2:1 MAX |
| Output VSWR
|
3:1 MAX |
| Load Mismatch
|
Load VSWR = 8:1
All phase angles with no degradation in power output |
| Frequency Band
Switching |
Control via isolated
base BNC connector on the back panel. TTL /CMOS compatible
signal for selecting operating amplifier module.
Low Level SLCT IN (0V) or SLCT Open amplifier A
High Level SLCT IN (5V to 12 V) amplifier B |
| Harmonic level
@ 10 W |
< - 30 dBc ,
-20 dBc or better for third harmonic |
| Spurious Output |
Greater than 50
dBc |
| RF Input / Output
connectors |
"N" type
Female on rear panel |
| Power Source |
AC Input: 100 to
120 VAC / 200 to 240 VAC, 50/60 Hz |
| Power connection |
EMI / RFI Filter
with IEC Standard Power Entry |
| Cooling |
Forced air |
| Dimensions (with
hardware) |
H 95 x W 480 x
L 419 mm, (H 3.75" x W 19" x D 16.5") |
| Weight |
~ 8 kg, (18 lbs.) |
| Mounting |
Stand alone unit.
(Front panel fits rack mount) |
| Case |
Front Panel and
Cover: T&C Platinum |
| Operating Temperature
|
0°C to 35°C |
|
|