SUT01LF-5B, STEP-UP TRANSFORMERS
FOR IMPEDANCE MATCHING

Most RF Power Sources are designed and optimized to deliver power into an impedance of 50 Ohms. In a power delivering system where the source and load impedance differs by more than 2:1, a matching element can improve efficiency.

T&C offers a variety of LF Band matching transformers for high and low impedance load applications.

The table below presents some standard impedance ratios offers by T&C.

 
 

SPECIFICATIONS: General

  • ENCLOSURE: W 4" x L 4" x H 3" (104 mm x 102 mm x 76 mm)
    Deep-Drawn Enclosure, ZERO Corp., #Z64-64A
  • CONNECTORS: BNC Input/Output

    SPECIFICATIONS: Performance

    Output Impedance's available. (Z in = 50 Ohms) Frequency Range 0.2 MHz to 3MHz minimum. Peak performance from 0.4 to 2 MHz. Low power operation possible up to 4 MHz or down to 0.1 MHz (50W max).
    Z IN
    Z OUT
    IMPEDANCE
    RATIO
    CONTINUOUS
    PWR INPUT
    (Without cooling)
    MAX.PWR INPUT
    PEAK VOLTAGE
    50 Ohms
    200 Ohms
    1 : 4
    100 W
    200 W
    ~ 400 V p-p @ 100 W
    50 Ohms
    ~310 Ohms
    ~1 : 6
    100 W
    200 W
    ~ 500 V p-p @ 100 W
    50 Ohms
    450 Ohms
    1 : 9
    100 W
    200 W
    ~ 600 V p-p @ 100 W
    50 Ohms
    ~610 Ohms
    ~1 : 12
    100W
    200W
    ~ 700 V p-p @ 100 W
    50 Ohms
    800 Ohms
    1 : 16
    100 W
    200 W
    ~ 800 V p-p @ 100 W