SUT02LF STEP-UP TRANSFORMERS
FOR IMPEDANCE MATCHING

Most RF Power Sources are designed and optimized to deliver power into an impedance of 50 Ohms. In a power delivering system where the source and load impedance differs by more than 2:1, a matching element can improve efficiency.

T&C offers a variety of LF Band matching transformers for high and low impedance load applications.

The table below presents some standard impedance ratios offers by T&C.

 
 

SPECIFICATIONS: General

  • ENCLOSURE W 4" x L 4" x H 3" (104 mm x 102 mm x 76 mm)
    Deep-Drawn Enclosure, ZERO Corp., #Z64-64A
  • CONNECTORS 1 : 4 and 1 : 9 -- BNC Input/Output
    1 : 16 and 1 : 25 -- BNC Input/Output HV Connecto

SPECIFICATIONS: Performance
Output Impedance's available. (Z in = 50 Ohms) Frequency Range 50 kHz to 1 MHz

Z IN Z OUT IMPEDANCE
RATIO
CONTINUOUS
PWR INPUT
(Without cooling)
MAX.PWR INPUT PEAK VOLTAGE
50 Ohms 200 Ohms 1 : 4 100 W 300 W ~ 560 V p-p @ 200 W
50 Ohms 450 Ohms 1 : 9 100 W 300 W ~ 840 V p-p @ 200 W
50 Ohms 800 Ohms 1 : 16 100 W 300 W ~ 1120 V p-p @ 200 W
50 Ohms 1250 Ohms 1 : 25 100 W 300 W ~ 1400 V p-p @ 200 W
 
         