Technical data for the CT6003S
System consists of four Major Functional Blocks
1. CT6003 Process Controller Assembly
2. CT6002 Light Meter Assembly
3. AG0201HV-XS Generator
4. Universal software package, GUI for analysis.
CT 6003 Process Controller is a key component
of the Tester. It consists of 6 major functional blocks:
- Analog and interfaceBoard Assembly. It is responsible
for interfacing the High Voltage RF Generator, CT 6002 Light
Meter, High Voltage DC Power Supply with microprocessor
board.
- Microprocessor Board Assembly. It is the core of the controller
and responsible for all functions of the system.
- Front Panel Control and LCD Display provides method of
Human Interface. It accesses the setting of parameters and
reads back the test results.
- AC to DC House Keeping Power Supply provides
all the necessary electrical energy for the Controller
to operate.
- AC to DC Controllable Power Supply provides
high DC voltage for CT 6002 Light Meter. Its output is
set to a default of ~500 VDC and is changed for 300
to 750 VDC during the test in automatic mode of operation.
- Bottom Interface Panel provides all necessary
connections within the System:
• AC Power In. IEC type connector for universal
100 to 120 and 200 to 240 +/-10% VAC,
47 to 63 Hz.
• CT 6003 controller to AG 0201 HV-XS Generator.
• High Voltage DC output to photo multiplier.
• Photo multiplier output to analog interface.
• Switch In — test request signal to the controller.
Number of settings
N = 1 to 15
Lamp Evaluation Methods
Time Method and Decay Integration Method
Test Modes
Operation Mode - production applications for QC Testing
Test & Edit Mode - laboratory evaluation of lamps
HV RF Generator V-Max Pulse
100% default setting; 0 to 100% scale, 1 % steps
HV RF Generator Pulse Width
100 ms default setting; 0 to 250 ms scale, 10 ms steps.
|
|
Plasma Hold
Up Time
40 ms default setting; 25 to 250 ms scale, 1 ms steps.
Plasma Hold Up Voltage
80% default setting; 5 to 100% scale, 1% steps.
Time Method Threshold Level
20% default setting; 5 to 100% scale, 1% steps.
Time Method Threshold Time
100 us default setting; 10 to 13000 us scale, 10 us steps.
Decay Integration Method Area
2000 default setting, 100 to 65 500, 50 units step.
Light Meter Photo Bias V
Initial HV DC Level provided to Light Meter in order to create
the best for the lamp measurement condition. 50% default setting,
1 to 100 % scale, 1 % steps.
Reject Delay
Amount of time needed between test and action to remove the
defective lamp under test from the conveyor 400 ms default
setting; 250 to 1000 ms scale, 10 ms steps.
Reject Time
Amount of time needed for action to remove the defective lamp
after negative test from the conveyor 250 ms default setting;
100 to 500 ms scale, 10 ms steps.
Statistics
Bad Counter capacity: up to 1 000 000
Good Counter capacity: up to 1 000 000
External Communication
SubD 9 RS232 I/O for Graphic User Interface or other computer
communication. Bottom Interface Panel. ETHERNET - optional
on special request
Graphic User Interface, GUI
Universal Software Package provided with support for Microsoft
Excel spreadsheets.
Sampling of the Test Results Data
Test Mode: automatically uploads to PC buffer.
Operation Mode: uploads on GUI request.
AC Power Source
100-120, 200-240 +/-10% VAC, 47 - 63 Hz, 75 VA, Bottom Interface
Panel via IEC Standard connector.
Cooling
No special cooling is required.
Dimensions
(H 370 x W 275 x D 145) mm
( 14.6” x 10.9” x 5.8” )
Weight
3.5 kg, 7.7 lbs.
|
|