STANDARD FEATURES
- Typical Output: P1dB = 53 dB
- Linear Output: 100 W with harmonics -25 dBc
- Power Meter:
RMS measurement of forward and reflected power.
- AGC or
Power leveling: Gain control of ± 0.5 dB
- Data Acquisition:
Communication port for status monitoring and power measurement.
Compatible with IO-TECH and
NATIONAL INSTRUMENT Data
OPTIONAL FEATURES
- RS-232/EIA-232 Communication
APPLICATIONS
- Communication transmission
- EMC testing
- General laboratory use.
SPECIFICATIONS
| DESCRIPTION |
RANGE/CHARACTERISTIC |
| Class of Operation |
A class in low power output, AB class
at high power levels |
| Frequency of
Operation |
10 kHz to 12 MHz +/- 1 dB
10 kHz to 19 MHz with AGC ON
|
| RF Power Output |
100 W typical LINEAR
300 W from 200 kHz to 4 MHz
100 W from 4 MHz to 14 MHz
<100 W from 14 MHz to 20 MHz and
20 kHz down to 10 kHz |
| Gain |
53 dB, @ 100W /
1 MHz
+/- 1dB 75 KHz to 14 MHz
+/- 2dB 10 KHz to 16 MHz
AGC option +/- 0.5 dB through the band |
| RF Power Input Drive |
-20 dBm to 0 dBm (1 mW) typical, +5
dBm max |
| Input and Output
Impedance |
50 Ohm Input
RF Output optimized for 50 Ohm resisitive load. |
| Input VSWR |
2:1 max |
| Output VSWR |
3:1 max |
| Output VSWR Protection |
75 W max. reflected power internal
limit |
| Harmonic level
@ 150 W |
> - 30 dBc ,
-20 dBc or better for third harmonic |
| RF Input / Output connectors |
BNC Female for INPUT and OUTPUT |
| Spurious Output |
- 76 dBm equivalent noise level
generated by internal circuits
- 24 dBm continuous level noise present at the amplifier output in 70 kHz
to 150 kHz band |
| Power Source |
AC Input: 90 - 130 VAC, 180 - 240
VAC, 47 to 63 Hz internally user selectable |
| Power connection |
EMI / RFI Filter with IEC Standard
Power Entry |
| Cooling |
Forced-air; Temperature controlled |
| Acoustic Level |
45 dBa @ maximum
fan speed and temperature |
| Operating Temperature |
32 to 95 F (0 C to 35 C) |
| Humidity |
80% |
| Dimensions |
H 135 x W 360 x L 385 mm, (H 5.25"
x W 14" x D 15") |
| Case |
Chassis: yellow
iridite. Front Panel T&C off-white. Cover T&C glossy black. Designed
to meet EMI / RFI requirements. |
| Mounting |
Stand-alone unit. Other options available per
customer specification. |
| Weight |
~ 28 lbs (13 kg) |
REAR PANEL CONNECTOR SIGNAL DESCRIPTION
Analog
and Digital I/O (Sub-D25 Connector)
| PIN # |
SIGNAL FUNCTION |
INPUT/OUTPUT |
DESCRIPTION |
| 1 |
REV LIMIT |
OUT |
TTL Compatible:
H = RF Out Limit
L = Normal operating condition at low VSWR
NOTE: This output indicates that output power level was automatically
reduced under load mismatch condition.
|
| 2 |
REV POWER
METER |
OUT |
Linear voltage
output, 1 Vdc = 100 W (w/0 dBm Input) |
| 3 |
FWD POWER METER |
OUT |
Linear voltage output, 1 Vdc =
100 W (w/0 dBm Input) |
| 5 |
EXT RF POWER
REF |
IN |
Linear voltage
input, 1 Vdc = 100 W (w/0 dBm Input) |
| 8 |
EXTERNAL CONTROL SELECT |
IN |
TTL Compatible:
H = Remote Control Active
L = Front Panel Control |
| 9 |
HEAT SENSE |
OUT |
TTL Compatible:
H = HOT! Heat problem,
L = normal operating conditions.
NOTE: This output indicates that over temperature condition has occurred.
|
| 11 |
POWER ON |
OUT |
TTL Compatible:
H = Power ON
L = Power OFF
NOTE: DC power applied to control circuit. Indirect meaning: AC is ON.
|
| 18/19/21 |
SIGNAL COMMON
(Internal AGND) |
N/A |
Connected to
Internal Ground AGND |
| 18/19/21 |
SIGNAL COMMON
(Internal AGND) |
N/A |
Connected to
Internal Ground AGND |